PHYSICAL FEATURES
Fire Resistance
The most important
requirement in any building is fire safety. To this end, HBD provides excellent
protection from fire and out performs all other building material's results
achieved in standard fire tests contained in various parts of British Standard-
476. HBD Calcium Silicate Boards have Class-1 Surface Spread of Flame with
Ignitability as "P"- not easily ignitible, hence can provide good
fire resistance in the range of 30 minutes to 240 minutes, depending on the
construction design. The fire test methods used are:
Non-Combustibility
Building materials
are classified as either non-combustible or combustible according to their
behavior when tested to BS 476-Part - 4:1970. This test provides a measure of
the propensity of materials to generate heat and flames under standardized heat
exposure conditions. It represents the highest and most stringent standard for
the fire performance of materials. HBD Calcium Silicate Board has gone through
this test and has been rated as Non-Combustible by CBRI, Roorkee.
Surface Spread Of
Flame
This test, as
specified in BS-476-Part-7: 1971, is used to determine the tendency of
materials to support the spread of flame across their surfaces. Materials are
classified Class-1 to Class-4, in descending order of performance. These
classifications are applied mainly to wall and ceilings. In this test too, HBD passed
with the highest rating of Class-1.
More information, please visit at www.hocre-board.com or send email to info@hocre-board.com